Operation Pressure Range Of Micropump mp6

Q What is the operation pressure range of the micropump mp6?

A The allowed differential pressure (inside pump to surrounding) is roughly 1.2 bar (120 kPa). However we have found that pumps could withstand 2 bars too, but we can’t guarantee this as we don’t have so much data about this. However, if higher pressures are applied instantly the pump may be destroyed; slow increasing/decreasing pressure is ok.

In series connection the pumps can generate more pressure than one single pump. In such a system we have achieved 20 psi (1.37 bar or 137 kPa) without destruction of the last pump in line. But again we guarantee only the 1.2 bar as these are tested in production.

Leave a Reply

Your email address will not be published. Required fields are marked *