Operation Temperature Range Of Micropump mp6

Admin/ April 19, 2018/ Micropumps/ 0 comments

Q What is the operation temperature range of the micropump mp6? A The data sheet mentions 0-70°C, but this is based on water. Zero simply because of ice creation, because ice has an expanding character and may destroy the pump. This is actually the cause for the storage concern here too. At a temperature of 70°C water begins to create air bubbles

Read More

Temperature Ranges for Storage Of Micropump mp6

Admin/ April 17, 2018/ Micropumps/ 0 comments

Q In which temperature ranges can the micropump be stored? A As long as the pump is stored without any liquid, i.e. water, there is no known limit to negative temperatures (Celsius). Positive temperatures are limited to ~130°C, regardless of liquid inside, as at that temperature the piezo ceramic and the applied adhesives will start to deteriorate.

Technical Specification Of mp6-OEM Controller

Admin/ April 17, 2018/ Electronics/ 0 comments

Q What are the technical specification of the mp6-OEM controller? A This controller IC is designed for the integration of the pump into a small space. The compact design allows a broad variety of application fields. Due to the optimized energy consumption it is possible to create unplugged systems. Battery operation allows mobile applications. Please note that the mp6-OEM is not equipped

Read More

Maximum Pressure Of Micropump mp6

Admin/ April 12, 2018/ Micropumps/ 0 comments

Q Which maximum pressure can the micropump mp6 achieve? A With the current design of the mp6 the maximal pressure to achieve is limited by the actuator. It can generate only a certain force, once this force is reached the actuator doesn’t move anymore. Due to the tolerances of the actuator this force limit is no exact value. So far we have

Read More

Lowest Possible Flow Rate

Admin/ April 10, 2018/ Micropumps/ 0 comments

Q What is the lowest flow rate that can be achieved with the micropump mp6? A The lowest flow rate is very dependent on the conditions in the customers test system. Generally a flow rate of about 20 µl/min for liquids can be achieved in most cases. With thorough optimization much lower rates can be achieved. In order to ensure stable pump

Read More